[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [heathkit] Heathkit SB400 low output
Bob, Many thanks for that. I have already replaced all the resistors for precisely the reasons you state and resoldered the joints. I had considered replacing the bypass caps, but that would have affected all bands and the caps seldom fail (I think). That just leaves the coils. I don't have a Q-meter: I read somewhere that the old coil slugs lose permiability over time and maybe this is true? I am not sure how the the slugs could deteriorate. The circuit is so simple that there is simply nothing else to replace. Upon further reflection, I think that the problem may be that the SB400 loads the oscillator too much. I added a double RCA adaptor to read the HFO frequency with a (digital) frequency meter and it pulled the HFO frequency quite a bit (but still dead with, or without the meter on 40m). I notice that the later SB301 instructions for the interconnect lead specifies "must be RG-62/U cable 24" long supplied with SB-301 Receiver". So perhaps that is critical? (RG-62/U 93 Ohm coax seems impossible to find in NZ). Maybe this is a design fault (the reason I checked the SB301 instructions was to see if there had been a mod)? What circuit did you use for a buffer, please?- that may be the best way to go. Alternatively, do I just add some capacitance between grid and plate? I have to say that I get good sig reports with the rig and (other than 40m) it is much nicer to use than my fancy silicon rig with DSP etc., etc., 73 Robin ZL4IG -----Original Message----- From: G3OOU@aol.com [mailto:G3OOU@aol.com] Sent: Thu 26/03/2009 21:55 To: heathkit@cyberventure.com; Robin McNeill Subject: Re: [heathkit] Heathkit SB400 low output Hi Robin I would check that the components in the oscillator circuit are still within tolerance, particularly the resistors. Carbon composition resistors go high over a long period of time and I threw out my "new old stock" of carbon resistors as they were 30+% high. Check the oscillator coils for dry joints etc and if you have a Q bridge measure the coils on that. Also make sure that the valveholder sockets are not oxidised. If you disconnect the HFO lead to the SB400 does the SB300 oscillator work correctly? I found it useful to monitor the HF oscillator grid current with a test meter when I did my rebuild, re-alignment and subsequent tests with an SB401. You need to keep the interconnecting lead as short as possible to minimise loading the SB300 oscillator. It was designed to work in this mode so it should be possible to make it work correctly. However, in my particular case, I installed a buffer in my SB301 as I needed to use longer interconnect leads in my station console. 73 Bob G3OOU G-QRP 6907 _www.g3oou.co.uk_ (http://www.g3oou.co.uk/) ------------------------------------------------------------------------------------- This Message has been successfully scanned by Mail Marshal at Venture Southland Please forward your enquiries to enquiry@venturesouthland.co.nz ------------------------------------------------------------------------------------- Attention: The information contained in this message and or attachments is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the Southland District Council and delete the material from any system and destroy any copies. Ph - 64 3 2111400 Fax - 64 3 2111401 Email - enquiry@venturesouthland.co.nz ------------------------------------------------------------------------------------- Please consider our environment... do you really need to print this email?
Tech Resources | Related Sites | Special Features | Listserv
Home | History | Hi-Fi & Stereo | Ham Radio | Test Equipment | Computers | Other
Copyright © 2008 Cyberventures Unlimited. All Rights Reserved. Terms of Use
The Heathkit equipment shown on this website is no longer manufactured and is shown here for historical purposes. |