[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [heathkit] Adding a Fuse to the IM-103
Parts needed: 3/16 amp slow blow fuse with appropriate sleeving. Remove the line cord that goes to terminal 2 on the terminal strip. Connect it to terminal 18. Connect the fuse in sleeving between terminals 18 and 3. Connect a wire between terminals 2 and 3. Solder all connections. Affix a label on the chassis near the circuit board to identify the fuse rating. On pages 12 and 13 of the manual indicate a fuse in the line from the AC plug to D1. On pages 2 and 14 add the new parts (346-6 Large sleeving, 390-362 Fuse label, 421-40 3/16 amp slow blow fuse) Add a note to the circuit description on page 12. Consider yourself protected. 73, gary =========////////========= Gary H. Harmon, Jr. - K5JWK 6003 Archwood San Antonio, TX 78239-1504 Home 210.657.1549 210.884.6926 Cell